        RT-11 V05.04 Customization Patches - Offset Symbol Definitions
        --------------------------------------------------------------

     The RT-11 Installation Guide contains customization patches for the moni-
tors  and  the  utilities.   As  described  in the manual, the addresses to be
patched are defined as symbols, not absolute addresses.  The values of symbols
for  monitor customization patches are obtained from the link maps distributed
with RT-11 as the files RTBL.MAP, RTSJ.MAP, RTFB.MAP, and RTXM.MAP.

      The link maps for the utilities are not  distributed  however,  and  the
following symbol values should be used to apply customization patches to them.
The section number refers to the relevant section in  the  RT-11  Installation
Guide.


2.7.5	Changing the Default Order of Directory Listings

	SWS = 6372


2.7.6	Changing the Number of /Q Program Sections LINK Allows

	QSWNUM = 1440


2.7.7	Changing the Size of LINK's Library Module List

	LMLSIZ = 1434


2.7.8	Changing the Size of the QUEUE Work File

	QSIZE = 1000
	QCBLK = 2716


2.7.9	Modifying EDIT

2.7.9.1	Size of the Text Window -

	DSARG = 17704


2.7.9.2	Terminals with Nonstandard ESCAPE Code -

	ALTMDE = 11053


2.7.12	Modifying BATCH to Save Space

	BASE = 0

	Offset for:	..RDIR = 30415
			..RMAC = 31035
			..RFOR = 31046
			..RLIN = 31065
			..RPIP = 31100
			..RBAS = 31117


							Page 2

2.7.13	Modifying LINK to Change the Default SYSLIB Device

	SYSLIB = 2300

2.7.14	Modifying the Help Text

	..HLP1 = 10
	..HLP2 = 13

2.7.17	Setting VTCOM Default Dial String

	For VTCOM.REL:

	..DIAL = 13007

	For VTCOM.SAV:

	Segment 1
	..DIAL = 31275



2.7.36	Changing the Default Number of Directory Segments

	SEGTBL = 11176


2.7.37	Changing the Banner Page Width

	(NOTE: for ..NB1 and ..NB2, open those offsets as bytes. Do that by
	typing a backslash (\) under the new? display. That reopens the entire
	display for each offset in byte entry mode. The values documented for
	..NB1 are correct; use them. For offset ..NB2 (old value 40), enter
	the new value 15. For offset ..NB2+1 (old value 40), enter the new
	value 12. At offset ..NB2+2, enter CTRL/Z <RET>, and continue the
	patch as documented.)

	..NB1 = 4756
	..NB2 = 5145
	..NB3 = 13116


2.7.38	Modifying Listing Page Length in LINK

	LINPPG = 1436


2.7.41	Supporting Bad Block Replacement in User-Written Handlers

	ARDPS = 11452
	SRDPS = 11462

							Page 3

2.7.42	Supporting User-Written Magtape Handlers

	MTDPS = 11444
	PIPMT = 7520
	MDUPMT = 5622


2.7.44	Changing Default File Type of Logical Disk Files

	..LDEX = 6500		! for LD.SYS
	..LDEX = 6472		! for LDX.SYS


2.7.45	Changing QUEUE to Allow First Form Feed

	..DOFF = 2624


2.7.46	Changing Listing Page Length in MACRO and CREF

	MACRO:

	PGSIZE = 2424

	CREF:

	PGSIZE = 1000


2.7.48	Limiting Amount of Memory KEX Requests

	..MAXM = 1306


2.7.49	Changing MACRO's Default .LIST/.NLIST Options

	LCBITS = 2430 


2.7.50	Changing MACRO's Default .ENABLE/.DISABLE Options

	EDBITS = 2426 


2.7.51	Modifying KED Default File type

	Modifying edited file default extension for KED/K52/KEX:

	..EEXT = 2372			! for KED
	..EEXT = 2272			! for K52
	..EEXT = 1310			! for KEX

	Modifying inspected file default extension for KED/K52/KEX:

	..IEXT = 2374			! for KED
	..IEXT = 2274			! for K52
	..IEXT = 1312			! for KEX

							Page 4

2.7.52	Changing SPOOL's Work File Size

	..SPSZ = 2240


2.7.53	Changing SPOOL's Output Devices

	..SPSO = 2224


2.7.54	Changing LINK for Default 132-Column Link Map and Global
	Cross-Reference Table

	..WDSZ = 4170


2.7.55	Increasing Default Size of MACRO-11 Work File

	WRKSIZ = 2440


2.7.56	Changing Name and Default Device for UCL.DAT

	..UCLD = 1002

        Changing UCL Data File Error Message Name (See V5NOTE.TXT)

        ..ERR = 2430


2.7.57	Suppressing Dynamic Allocation of a Region for IND

	..ALRG = 3702


2.7.58	Changing the Size of UCL.DAT

	..CMDS = 1000


2.7.59	Changing Default VTCOM SEND Speed

	For VTCOM.REL:

	..FAST = 16476

	For VTCOM.SAV:
	
	Segment 1
	..FAST = 34764


2.7.60	Modifying the System MACRO Library SYSMAC.SML
	(See page 1-1, Programmer's Reference Manual)

	..SYSM = 4


							Page 5

2.7.61  Modifying the VTCOM Default Dial String Prefix

	For VTCOM.REL:

	..DPFX = 12767

	For VTCOM.SAV:

	Segment 1
	..DPFX = 31255


2.7.62  Modifying the VTCOM Default Dial String Suffix

	For VTCOM.REL:

	..DSFX = 13057

	For VTCOM.SAV:

	Segment 1
	..DSFX = 31345


2.7.64  Changing the Number of Bad Blocks That BUP Accepts
		(patch located in V5.4 Release Notes)

	..MBAD = 2114


2.7.65  Modifying ODT.OBJ to Not Require a Monitor
		(patch located in V5.4 V5NOTE.TXT)

	..GVAL = 1502




------ end of CUSTOM.TXT ------
